Overland libraryxpress driver
Knowledge Base Search. Use the form below to enter your search criteria. By default, all content is searched except for document comments. If you wish to search comments as well as everything else, click "Also Search Comments" below. My Watches Print This Page.
MS Exchange snap server. OS snap server. My Watches. Print This Page. Many usbvideo. To run Windows Update, please follow these easy steps:. If Windows Update failed to resolve the usbvideo. Please note that this final step is recommended for advanced PC users only. If none of the previous three troubleshooting steps have resolved your issue, you can try a more aggressive approach Note: Not recommended for amateur PC users by downloading and replacing your appropriate usbvideo.
Please follow the steps below to download and properly replace you file:. If this final step has failed and you're still encountering the error, you're only remaining option is to do a clean installation of Windows To avoid data loss, you must be sure that you have backed-up all of your important documents, pictures, software installers, and other personal data before beginning the process.
If you are not currently backing up your data, you need to do so immediately. Microsoft typically does not release Windows SYS files for download because they are bundled together inside of a software installer. The installer's task is to ensure that all correct verifications have been made before installing and placing usbvideo.
An incorrectly installed SYS file may create system instability and could cause your program or operating system to stop functioning altogether. Proceed with caution. You are downloading trial software.
Subscription auto-renews at the end of the term Learn more. Microsoft Windows SYS usbvideo. How to Download Usbvideo. Average User Rating. All rights reserved. View Other usbvideo. Original Filename: usbvideo. What are usbvideo. Some of these errors include: usbvideo. The file usbvideo. If a DLTtape cartridge is dropped Inspect the cartridge carefully before you insert it into a LibraryXpress magazine or any drive.
Check the case for cracks, split seams, or distortion. Shake the cartridge and listen. A rattle sound indicates a broken part inside. Inspect the leader by opening the cartridge door as shown in Figure The leader should be wound tightly to the spool. The leader loop should appear as shown below, protruding at a slight angle from the case. Figure Inspecting Leader of DLTtape Cartridge If the leader loop is torn, missing, or out of position, or if the tape leader is creased and loosely wrapped around the spool, do not use the cartridge.
The hub should seat precisely in the access opening. The hub is held in place by spring tension, and should deflect and bounce back freely.
If the hub is rigidly jammed to the side or stuck down inside the body, the cartridge is broken. Do not use the cartridge! Such labels can come off inside the equipment causing damage. Write Protection Figure shows the write protection switch of a DLTtape cartridge: Figure DLTtape Cartridge Write Protection Switch 60 Chapter 3 - Operation To enable data recording, slide the write protect switch to the right so that no orange color is visible through the window in the write protect switch.
To write protect the DLTtape cartridge, slide the write protect switch to the left until the orange indicator shows through the window on the write protect switch.
As a result, you use exactly the same procedure to load and unload. When a drive is idle, it has a cartridge loaded, and is awaiting instructions. Note: If the control panel has been locked by means of the Security Menu, the screen reports the locked status instead of displaying the Main Menu. If you do not know the unlock code, contact your system administrator. Line 2 shows the top item in a scrollable list of sources.
This indicates that the T button may now be used to scroll through the list, and that the top item on the list is displayed. This indicates that there is one or more items above the item displayed on line 2. Let us assume that you want to load the cartridge that is in Slot 4 into any available drive.
Use the T button to scroll line two to Slot 4. The display appears as shown in Figure Notice that in Figure , two changes occur in the display. Note that there is no … at the end of line 1. There are no additional choices because you have selected a slot as the source, so the destination must be a drive.
Press the Enter button to select DLT1. In response, the confirmation screen in Figure appears. If the confirmation screen does not show your intended source and destination, press the Escape button to return to the From entry screen. When you press the Enter button, the screen shown in Figure appears. If the source is a drive, the word Unload appears in place of the word Load on line 4.
As illustrated in Figure , the screen has been updated to show that there is now a cartridge in DLT1 and that Slot 4 is empty. There are User Diagnostics on the Demo submenu that you can use to check the operation of the Base Module. Occasionally, new firmware is issued by Overland Data. Firmware upgrades must be performed by qualified service personnel. This chapter tells you how to clean the drives. The Demo Menu is described in Chapter 5 - Troubleshooting.
Using the Cleaning Cartridge The cleaning cartridge is similar in appearance to the cartridge shown in Figure The command to run the cartridge is issued from the control panel. The procedures that follow tell you how to install a cleaning cartridge, how to clean a drive, and how to remove the cleaning cartridge.
To use this option, you must reserve a slot for a cleaning cartridge using the Reserve Slots option. Installing a Cleaning Cartridge 1. Examine the Default Screen on the Control Panel to determine whether any cartridges are loaded into the drives.
If so, then unload each as described in Chapter 3 - Operation. Using the key provided if necessary , unlock the Magazine Security Lock on the front panel. Remove the magazine from the Base Module. Remove any cartridge present in Slot 1 the slot nearest the handle. Insert the cleaning cartridge into Slot 1.
You can use any slot, but using Slot 1 saves some keystrokes. Insert the magazine into the Base Module. You can also dedicate a slot for a cleaning cartridge by using the Reserved Slots Configuration option. You can dedicate additional reserved slots. If there is one reserved slot it is the last slot in the magazine position If there is more than one reserved slot, reserved slot 1 will follow the last data cartridge slot as shown in Figure This also applies to the numbering of the cleaning slots when the reserved slots contain cleaning cartridges: Figure Reserved Slot Numbering Running the Cleaning Cartridge This procedure assumes that the cleaning cartridge has been installed into Slot 1 of the magazine.
At the Default Screen, press the Enter button. Press the T button twice to move the X next to Maintenance, then press the Enter button to select the Maintenance Menu. The display will show something similar to the following. Lines 2 and 4 are scrollable. Let us assume you want to clean DLT1.
Press the Enter button once to accept DLT1. The X moves to line 4 of the display. Press the Enter button again to use the cartridge in Slot 1. Note: If you are unable to use slot 1 for the cleaning cartridge, you can scroll line 4 to select another slot. Cleaning Confirmation Screen As the confirmation screen indicates, to execute the cleaning operation, press the Enter button. If the confirmation screen does not show your intended drive and cleaning cartridge, press the Escape button to return to the Cleaning submenu.
In that event, leave the lock in the unlocked position 1. Using the key provided if necessary , Unlock the Magazine Security Lock on the front panel. Remove the cleaning cartridge from the magazine. Insert any desired data cartridge into the slot vacated by the cleaning cartridge. Using the key provided, lock the Magazine Security Lock on the front panel optional. Some errors cause Fault Symptom Codes FSC to appear on the control panel display, along with a description of the fault.
The FSC codes are described later in this chapter. Platform Problems These errors arise out of incorrect installation and configuration. The most common characteristic of this type of error is that the Base Module appears to operate normally, except that no data can be interchanged.
You may not get an error code on the control panel. To identify an error as this type of problem, check your installation and configuration setup, referring back to Chapter 2 - Installation. General Drive Errors These errors usually result from a miscommunication between the controller and drive processors or involve a mechanical malfunction. In most cases, these types of errors report an error message and an FSC to the control panel. The only exceptions are power supply problems and display malfunctions.
The FSC can be used to determine a recovery procedure. Some error messages can be cleared by pressing the Enter button on the control panel, others by cycling the power to the module. Often the module will resume normal operation.
Other errors are repeated when the operation is attempted again. Such recurrent errors may require more extensive recovery procedures such as replacement of a part. To aid you in localizing persistent errors, there are user diagnostics available on the Demo Submenu. These are described at the end of this chapter. This chart should be followed in all cases. Fault Symptom Codes are listed in Table Each FSC is accompanied by a descriptive message and instructions for clearing the fault.
When a fault persists, you should look up the FSC in Table for a description of the error code. If you call your Technical Support representative about a fault condition, be sure to furnish the FSC to aid in identifying the problem. Generally a firmware bug. Comm Open Error The trace port could not be opened. Error A failure occurred when trying to initialize the Novram.
Error An error was detected while trying to download configuration data. Error The barcode comm port could not be opened. Error The real-time clock could not be initialized. Error An error occurred in the low-power ram initialization. Comm Open Error Failed to open a Slave comm port. Gross error status was returned by the SCSI chip. This usually means that the SCSI chip is in an illegal state. The SCSI chip rejected a command from the firmware. Not reported. Firmware error.
An interrupt was returned from the SCSI chip when one was not expected. An invald interrupt was returned from the SCSI chip. Status was returned from the control process when no command was active. An invalid request was received from the control process firmware error. Firmware Error. A message sent from the control process was not valid.
The control process sent a command while one was in process. The control process sent a message while one was in process. Would only occur during SCSI initialization.
Open Error Door Fault An invalid command was received by the control process. An unsupported configuration was detected. One of the DLT drives was in an invalid state This is caused by either attempting to fetch a cartridge from an empty drive, or stowing to a drive that already has a cartridge loaded.
Currently not displayed. An attempt to open a COM port failed. Firmware Error An error occurred while attempting to move the door. This also occurs if the MOVE is attempted with an invalid cartridge map. A command was received while the door was open. A command was received while the unit was in Menu mode.
An attempt was made to fetch a cartridge from a drive that is not in the unloaded state. This only applies when the system is configured for explicit unloads. An attempt was made to access a drive which is in an error state. The element is not available because the magazine is not installed. An invalid configuration was detected. The configuration jumpers on the main board may not be set properly. Firmware Error Ctl. Since commands are never sent in these modes, status cannot be received.
A command was received which was invalid for the current configuration. While trying to update the front panel, communication with one of the DLT drives was unsuccessful. Communication with DLT drive 1 was unsuccessful sequential mode. Communication with DLT drive 2 was unsuccessful sequential mode. While attempting to update the cartridge map, communication with one of the DLT drives was unsuccessful.
An illegal message type code was received. This can be the result of receiving a NULL type code, a status code without a command being active, or a command code while a command is currently active.
When trying to locate the unit attached to port x, the pass-thru elevator reached the top of rail. The pass-thru elevator did not travel a minimum distance to reach the top of its travel. Enter to reboot. The minute timer was exceeded when trying to fetch from a drive. Internal error only.
Not reported to the operator or host. Power Down, Wait 30 seconds, Power Up. Set if the Alternate Unload has not been selected. This currently applies only to DLTs with a controller microcode revision greater than During a remote fetch operation, the remote unit returned an error.
TACH errors were detected during an elevator movement. An elevator jam was detected during initialization. TACH errors were detected during passthru elevator movement. Communication with one of the DLT drives was unsuccessful. A command was issued but status was not returned. Currently unused. TACH errors were detected during a door movement. During initialization, the door was found to be in an improper state. Open Tach detected on elevator motor.
Open Tach detected on picker motor. Open Tach detected on door motor. A problem was encountered while trying to stow a cartridge to a drive. While attempting to fetch a cartridge, the picker was not able position properly within 16 attempts. While stowing to a drive, the initial push failed. An undefined picker position was specified. An undefined door position was specified. The picker stalled during an inventory. During a stow operation, the picker was not able to insert the cartridge into the bin.
While stowing to a bin, the picker moved too far. This generally occurs if the arm slips in between two cartridges during the final push. During a bin stow, the picker did not reach a position far enough to insure that the cartridge was fully inserted. The picker was not able to home properly after stowing a cartridge to a bin. The picker was not able to position to the cartridge notch while performing a bin fetch operation.
During a bin fetch, the picker stalled while attempting to pull a cartridge into the shuttle. The picker was not able to position to the cartridge notch while performing a drive fetch operation. During a drive fetch, the picker stalled while attempting to pull a cartridge into the shuttle.
During a stow operation, the picker was not able to insert the cartridge into the drive. The elevator was not able to position properly while attempting to recover an orphaned cartridge. The elevator was not able to position properly during an inventory. The elevator was not able to position properly during a fetch operation.
The elevator was not able to position properly during a stow operation. The elevator was not able to position properly during a home operation. The elevator stalled while attempting to open the DLT door. The pass-thru elevator was not able to position properly. Error Comm. User has chosen the Clean Drive menu selection, but all slot locations are currently devoid of tape cartridges. User has chosen the Clean Drive menu selection, but all DLT drive locations are currently occupied with tape cartridges.
A DLT, previously determined at boot-up to be attached, has not responded to a communication attempt. User has chosen the Clean Drive menu selection, but a DLT previously determined to be unloaded and now selected to be cleaned, has indicated the presence of a tape cartridge.
User has chosen the Clean Drive menu selection, but has specified a slot which contains an expired cleaning cartridge.
User has chosen the Clean Drive menu selection, but has specified a slot which does not contain a cleaning cartridge. A default setting was determined to be invalid. User has chosen the DLT Compression menu selection, but the chosen DLT has failed to successfully execute the compression mode change request.
0コメント